top of page

Fibula tumor resection: preserving the distal fibula with a patient-specific cutting guide

Isabelle Têcheur
4 hours ago
2 min read

A tumor sitting in the distal fibula leaves very little room between a safe resection and losing the bone that stabilizes the ankle. At Cleveland Clinic (Ohio, USA), Dr. Zachary Burke planned a resection that removed the tumor with a 1.5 mm margin while preserving the distal tip of the fibula.

The plan was delivered as a single 3D-Cut patient-specific cutting guide. Two details made the difference: a dedicated K-wire that confirms the guide's position before any fixation, and a cut geometry designed around keeping the distal segment.


The challenge: a distal fibula tumor next to the ankle

The tumor extended along the distal fibula, close to the lateral malleolus. Resecting the whole distal end would have been the simpler cut, but it would also have sacrificed the bone that supports lateral ankle stability.

The goal was to remove the tumor segmentally and keep the distal tip of the fibula intact. That meant two cutting planes placed precisely around the lesion, with no room for the guide to sit even a few millimeters off.


3D surgical planning: three iterations to save bone

The resection was planned in 3D from the patient's MRI, in close collaboration with the surgeon.

The first proposal used a 3 mm safe margin. At the surgeon's request, the cutting planes were brought 1.5 mm closer to the tumor in the final version, leaving more healthy bone in place. A second guide for a hemisection on the back table was also considered, before this step was performed freehand.

Final plan at a glance:

  • 2 cutting planes, 1.5 mm safe margin

  • Lateral approach

  • 1 patient-specific cutting guide, splitting into 2 cut blocks


K-wire positioning: checking the fit before fixation

The guide uses five 2.0 mm K-wires, and each one has a specific role. The most distal wire is a positioning wire only: it confirms that the guide sits in its single planned position before anything is fixed.

Once the guide is placed on the bone, this distal K-wire is inserted first. It is designed to point to the very distal tip of the fibula: its trajectory confirms that the guide is correctly positioned before the fixation K-wires are inserted.


Why patient-specific guides matter in bone tumor surgery

In bone tumor surgery, every millimeter of margin and every centimeter of preserved bone count. This case shows how patient-specific planning lets the surgeon tighten the margin, keep the distal fibula, and verify the guide's position on the table with a single K-wire.



 
 
 